Clearwater
Learning

Topics / Treatment and supply / 19 of 22

30 mg/L BOD

Wastewater treatment

The US monthly average limit on five-day biochemical oxygen demand for secondary treatment. Raw sewage typically comes in near 200 mg/L, and a plant has to take out at least 85 percent.

What goes down the drain is about 99.9 percent water. The small remainder is what matters, chiefly because of what it does to a river. Organic matter feeds bacteria, the bacteria consume oxygen as they eat, and a stream that receives raw sewage can lose its fish over miles. Harold Streeter and Earle Phelps put that into equations in 1925, in their US Public Health Service work on the Ohio River: the oxygen sag, a dip in dissolved oxygen below an outfall followed by a slow recovery downstream.

Hence the unit around which sewage treatment is organized. Biochemical oxygen demand (BOD) measures how much oxygen microbes use in breaking down what’s in a sample. The standard BOD5 test seals a diluted sample in a bottle in the dark at 20 °C for five days and records the drop in dissolved oxygen.

A short history

Cities once ran their sewers straight to the nearest river. London’s stench in the hot summer of 1858, the Great Stink, finally pushed Parliament to fund Joseph Bazalgette’s intercepting sewers, which moved the discharge downstream without treating it. The treatment came later. In the US, the Cuyahoga River’s fire of 1969 became a symbol, though the river had burned before. The Clean Water Act of 1972 made secondary treatment the national minimum for public plants, backed by federal grants that built thousands of them.

Stages

Flow through an activated sludge plantScreens and a primary clarifier feed an aeration tank, then a secondary clarifier, then disinfection and the river. Settled sludge returns from the secondary clarifier to the aeration tank, and waste sludge goes to digestion.ScreensgritPrimarysettlingAerationmicrobes eat BODSecondarysettlingDisinfectUV or ClriverReturn sludgeWaste sludge to digestionPrimary sludge
Simplified flow sheet. The return line is the invention: it keeps a large population of settled microbes in the tank.

Preliminary treatment gets rid of what would wreck the machinery. Screens catch rags and wipes, including the ones labeled flushable, and a grit chamber lets sand drop out.

Primary treatment is simple settling. Over a couple of hours in a large tank, heavy solids sink and grease floats. Typically this takes out about 60 percent of the suspended solids and 30 percent of BOD. Until the 1970s, that was all many coastal cities did.

Secondary treatment is biological, and the most common form is activated sludge, developed by Edward Ardern and William Lockett in Manchester in 1914. Sewage goes into a tank with a dense culture of bacteria and protozoa, and blowers supply oxygen. The microbes turn the dissolved organic matter into carbon dioxide and more microbes. The mix goes to a clarifier, the flocs settle, clear water leaves over the weirs, and much of the settled sludge returns to the head of the tank. The return line is the clever part. It lets the plant keep the microbes longer than the water, so a few hours in the tank is enough. Trickling filters and other attached-growth systems do the same job with a biofilm on a medium.

Disinfection treats the effluent with chlorine or UV before discharge, to bring down pathogen indicators.

Nutrients

Secondary treatment doesn’t take out most nitrogen and phosphorus, and those fuel algal blooms downstream. So many plants added tertiary steps. For nitrogen, one group of bacteria converts ammonia to nitrate with oxygen present (nitrification), and a second converts nitrate to nitrogen gas in a tank without oxygen (denitrification). Phosphorus can be precipitated with iron or aluminum salts, or taken up by bacteria that are cycled through anaerobic and aerobic zones.

Sludge and energy

Each process leaves solids. A large plant’s sludge is often stabilized in sealed digesters, where microbes produce biogas that’s about 60 percent methane, often burned on site to generate power and heat. The stabilized product, biosolids, can go to farmland under the rules in 40 CFR Part 503, to landfill, or to incineration. Land application is under scrutiny because of PFAS, and rules are changing. The aeration blowers are usually the plant’s largest energy user, and water and wastewater services are among the biggest energy costs of many US municipal governments.

Not everyone is on a sewer

About one in five US households uses a septic system: a buried tank that settles solids, and a drain field that lets the liquid soak into soil, which does the secondary treatment. It works well in the right soil with a tank pumped every few years. In wrong places it leaks nutrients and microbes to shallow wells and lakes.

Reuse

Treated wastewater is a reliable supply in a dry region. Much of it already reaches a downstream user by way of the river. Many plants supply irrigation water. Windhoek, Namibia, has blended advanced-treated wastewater into its drinking supply since 1968. Orange County, California, injects highly treated water into its groundwater basin, following microfiltration, reverse osmosis and UV with advanced oxidation. The result often beats the source water for purity, and public acceptance tends to follow good explanation.

Worked calculation A plant’s mass balance

An illustrative town plant takes 20,000 m³/day at 220 mg/L BOD. Effluent is at the 30 mg/L limit. Note that 1 mg/L equals 1 g/m³.

BOD in20,000 m³/day × 220 g/m³ = 4,400 kg/day
BOD out20,000 m³/day × 30 g/m³ = 600 kg/day
Removed4,400 − 600 = 3,800 kg/day
Removal efficiency3,800 ÷ 4,400 = 86%

Just above the 85 percent floor. At the common planning figure of about 60 g of BOD per person per day, 4,400 kg/day corresponds to around 73,000 people.

Worked calculation Time in the aeration tank

The aeration tank holds 6,000 m³.

Hydraulic retention time6,000 ÷ 20,000 = 0.3 days = 7.2 hours

Solids stay far longer, commonly 5 to 15 days, because they’re recycled. Two clocks run in one tank, and that’s what makes it work.

Worked calculation What the river sees

The plant discharges to a river with 5 m³/s of flow and background BOD of 1 mg/L. Assume full mixing.

River flow5 m³/s × 86,400 s/day = 432,000 m³/day
Mass from the river432,000 × 1 g/m³ = 432 kg/day
Mass from the plant600 kg/day
Total flow432,000 + 20,000 = 452,000 m³/day
Mixed BOD(432 + 600) kg/day ÷ 452,000 m³/day = 2.3 mg/L

Permit writers run this calculation at the river’s low flow. The US standard low-flow statistic is often the 7Q10, the lowest seven-day flow expected once in ten years. Halve the river and the same plant gets a different permit.

Where to check this

  • Metcalf and Eddy, AECOM (2014). Wastewater Engineering: Treatment and Resource Recovery. 5th edition. McGraw-Hill.
  • Ardern, E., and Lockett, W. T. (1914). “Experiments on the oxidation of sewage without the aid of filters.” Journal of the Society of Chemical Industry 33.
  • Streeter, H. W., and Phelps, E. B. (1925). A Study of the Pollution and Natural Purification of the Ohio River. US Public Health Service, Public Health Bulletin 146.

Full list on the sources page.