Topics / Treatment and supply / 18 of 22
4-log = 99.99%
How drinking water is treated
The US treatment requirement for viruses in surface water. Water engineers count in powers of ten, because getting 99 percent of the germs out of a river still leaves far too many.
Treatment is a chain of barriers, with each link dealing with what the last one left behind. How long the chain has to be depends on your source water. A deep, clean aquifer may need little beyond disinfection. A lowland river that carries farm runoff and upstream cities needs the whole train and sometimes more.
Getting particles out
River water is cloudy with clay, silt, algae and organic matter. Much of that is too small to settle in any practical time, and the particles carry a negative surface charge that keeps them apart. A coagulant, usually aluminum sulfate (alum) or an iron salt, neutralizes the charge. This happens in seconds in a rapid mix. Flocculation comes next: gentle stirring for 20 to 30 minutes so the tiny particles collide and stick into fluffy flocs. Stir too hard and they break up. Then the water moves slowly through a sedimentation basin for an hour or more, and most of the floc falls out as sludge.
Filtration catches the rest. In a rapid gravity filter water falls through a bed of sand, often topped with anthracite, at something like 5 to 15 m/h. Particles are held by contact with the grains inside the bed, so the filter isn’t working as a simple sieve. When the bed clogs, operators reverse the flow to wash it. Slow sand filters, the older design, run at about 0.1 to 0.4 m/h, and they rely on a living layer on the surface. They take up a lot of land and give excellent water with little chemistry.
The record of what filtration does is striking. James Simpson built the first big slow sand filter for a London water company in 1829. In the Hamburg cholera epidemic of 1892, the city drew unfiltered water from the Elbe and suffered thousands of deaths, while neighboring Altona, which had filtered its supply though it drew water downstream, escaped lightly. Robert Koch’s analysis of that contrast became a classic case.
Killing or inactivating what remains
Chlorine is the workhorse. Its first large continuous use in a US public supply came in Jersey City, New Jersey, in 1908, and typhoid fell sharply in the cities that took it up. Chlorine stays in the water after it leaves the plant, so a residual protects the distribution pipes as well. Ultraviolet light and ozone are strong disinfectants, but neither leaves a residual behind, so plants using them usually add a small chlorine or chloramine dose at the end.
Disinfection effectiveness depends on concentration and contact time, and the engineers’ measure is CT:
CT = C × T
C is the disinfectant residual in mg/L, and T is the time in minutes that the water spends in contact with it. Regulators publish tables of the CT needed for a certain kill at a certain temperature and pH. Cold water needs a lot more CT, and a high pH weakens free chlorine. Because tanks short-circuit, T isn’t the plain volume over flow. It’s the time for the first 10 percent of the water to get through (T10). A baffling factor accounts for that: about 0.1 for an unbaffled tank, up to about 1.0 for a long pipe.
Log removal
Regulations express treatment performance in powers of ten. One log is 90 percent removal, two logs is 99 percent, three is 99.9, and four is 99.99. Under the US Surface Water Treatment Rule, systems must achieve at least 3-log removal or inactivation of Giardia and 4-log of viruses. Later rules added 2-log for Cryptosporidium. Filtration earns credit and disinfection makes up the balance.
That last organism shows why you want more than one barrier. Cryptosporidium is highly resistant to chlorine, so filtration has to remove it. In 1993 a breakdown in filtration performance in Milwaukee, Wisconsin, during a time of high turbidity, led to the largest documented waterborne outbreak in US history, with an estimated 400,000 people ill. UV light turned out to work very well against it. In Walkerton, Ontario, in 2000, E. coli from farm manure entered a shallow well, the chlorination was inadequate and the monitoring was falsified, and seven people died. The public inquiry that followed is widely read in the trade.
A tradeoff
Chlorine reacts with natural organic matter to form disinfection byproducts, such as trihalomethanes, first found in drinking water in the 1970s. Regulators limit them, and plants handle this by removing organic matter before chlorinating, or by changing disinfectants. Nobody serious proposes giving up disinfection to avoid them: the WHO states plainly that the risks from byproducts are small next to the risks from inadequate disinfection. The art is in balancing the two.
Extra steps, by source
Depending on what’s in the source, plants might add activated carbon for taste, odor and some chemicals, aeration for iron or volatile compounds, ion exchange for nitrate or PFAS, lime softening for Hard water, or membrane filtration. Most also adjust pH and add a corrosion inhibitor, for reasons on the lead sheet. The water then has to get through hundreds of kilometers of pipe, which has its own risks: leaks, pressure loss, stagnation, and old mains. The treatment plant is only part of the system.
This sheet describes how the process works. What’s in your own tap water is in your utility’s report and the sheet on reading one will help with it. If there’s a boil-water notice, follow it.
Worked calculation What four logs means in organisms
Suppose 1,000,000 virus particles enter in a given volume.
| After 1 log (90%) | 100,000 |
|---|---|
| After 2 logs (99%) | 10,000 |
| After 3 logs (99.9%) | 1,000 |
| After 4 logs (99.99%) | 100 |
Each log takes the same amount of effort on a simple first-order model and removes a smaller absolute number. Credits add up: 2.5 log from filtration plus 1.5 from disinfection make 4.
Worked calculation CT through a contact tank
Tank volume 1,000 m³, plant flow 20,000 m³/day, baffling factor 0.5, free chlorine residual at the tank outlet 0.8 mg/L. These are illustrative. The required CT comes from the regulator’s table for the water’s temperature and pH.
| Flow per minute | 20,000 ÷ 1,440 = 13.9 m³/min |
|---|---|
| Theoretical detention | 1,000 ÷ 13.9 = 72 min |
| T10 | 72 × 0.5 = 36 min |
| CT achieved | 0.8 × 36 = 29 mg·min/L |
Flow doubles on a hot day and T10 halves, so operators either raise the dose or accept less margin. Better baffles get you more CT without a drop more chemical, which is why tanks get rebuilt.
Worked calculation Daily chlorine use
A dose of 1.5 mg/L at the same plant. A mg/L is the same as a g/m³, which makes this one easy.
| Dose | 1.5 g/m³ × 20,000 m³/day = 30,000 g/day |
|---|---|
| Chlorine used | 30 kg/day |
Where to check this
- Crittenden, J. C., Trussell, R. R., Hand, D. W., Howe, K. J., and Tchobanoglous, G. (2012). MWH’s Water Treatment: Principles and Design. 3rd edition. Wiley.
- World Health Organization. Guidelines for Drinking-water Quality. 4th edition with addenda.
- US Environmental Protection Agency. National Primary Drinking Water Regulations.
- Mac Kenzie, W. R., and others (1994). “A massive outbreak in Milwaukee of Cryptosporidium infection transmitted through the public water supply.” New England Journal of Medicine 331.
- O’Connor, D. R. (2002). Report of the Walkerton Inquiry. Ontario Ministry of the Attorney General.
- Evans, R. J. (1987). Death in Hamburg: Society and Politics in the Cholera Years, 1830-1910. Oxford University Press.
Full list on the sources page.